<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>alproof</ParameterFamily>
<LongName>
crtilt_pressure_delay
</LongName>
<Name>
cpd
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800_Proofing</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This parameter is obsolete after Spectrum firmware version 1.1. It is hardcoded
with 0 seconds.
</text></DescriptionText>
<DescriptionText><text>
The number of seconds to pre-pressurize the CR tilt cylinders in the opposite
direction that you want to move them.  This prevents the cylinders from slamming
in the direction they are moved, and allows us to let both direction solenoids
go idle when we aren't tilting or untilting the CR to prevent wear on the
sliders.
</text></DescriptionText>
</Description>
<Type>
uint32
</Type>
<Default>
<UnnumberedList>
<li>0 (obsolete after version 1.1)</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 5 seconds</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
Recent (Oct '97) solenoid and cylinder changes have proved that nothing bad
happens when this parameter is set to 0, so don't worry about it.
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:25 2008 PST
</Updated>
<Links>
</Links>
</Parameter>